{"title":"Thermocouples","description":"","products":[{"product_id":"rs-pro-3630250","title":"RS Pro K Type Thermocouple 1\/0.2mm diameter, -75°C → +250°C;  363-0250","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS PRO Type K Thermocouple\u003c\/h3\u003e\n\u003cp\u003eThis RS Pro Type K Thermocouple Temperature Sensor features a welded tip exposed junction for a fast response time. The twin-twisted leads have a durable Teflon PFA insulation and are terminated one end with a moulded miniature flat pin plug which is colour coded green in accordance with IEC. The moulded plug has a robust construction, providing a waterproof termination and enables a quick and easy connection.\u003c\/p\u003e\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eIEC-584-3 Class 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eMiniature moulded plug with robust design for quick connection and waterproof termination\u003c\/li\u003e\n\u003cli\u003eTemperature range of -75 to +250°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTest and Development\u003c\/p\u003e\n\u003cp\u003eTest and Measurement\u003c\/p\u003e\n\u003cp\u003eTemperature Mapping\u003c\/p\u003e\n\u003cp\u003eOEM Applications\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:363-0250\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3206\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable style=\"border-collapse:collapse;border-color:#ccc;border-spacing:0\" class=\"tg\"\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth style=\"background-color:#f0f0f0;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:18px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:bottom;word-break:normal\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eRS PRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e363-0250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eExposed Junction Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eThermocouple Type\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProbe Material\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eStandards\/Approvals\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eIEC,  RoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eMinimum Temperature Sensed\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e-75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e1\/0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eStandards Met\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161573077026,"sku":"3630250","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3630250-01_0b891128-f704-4b09-b550-6d3f4ab40bb9.webp?v=1792099227"},{"product_id":"rs-pro-3971264","title":"RS PRO Type K Thermocouple 150mm Length, 3mm Diameter, -40°C → 1100°C;  397-1264","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K Mineral Insulated Thermocouples with Plain Pot Seal and Lead\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K thermocouple temperature sensors that conform to IEC 584 standards with class 1 tolerance for optimum accuracy. These sensors or probes have a durable construction and feature a stainless steel 310 probe sheath and a PFA insulated lead. The mineral insulated flexible probe sheath can be bent and formed to suit a wide range of applications. The thermocouple has a single element insulated hot junction for a reduction in electrical interference and a plain pot seal with a temperature rating of 200°C.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is Mineral Insulation?\u003c\/h3\u003e\n\u003cp\u003eMineral insulation is used to insulate the thermocouple wires from one another and from the metal probe sheath that surrounds them. The sheath is filled with a highly compacted magnesium oxide powder that prevents the conductors from making contact with one another other than at the fixed junction. The high density of the mineral powder enables the thermocouple to have a rapid response as it promotes a fast heat transfer between the conductor and the sheath. Mineral insulation also helps to protect the thermocouple wire from environmental damage including corrosion, prevents electrical interference and allows the cable to be flexible whilst maintaining its mechanical strength\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDurable 310 stainless steel probe sheath for protection against corrosion and oxidation\u003c\/li\u003e\n\u003cli\u003eIEC 584 class 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eMineral insulation for flexibility, durability and high performance\u003c\/li\u003e\n\u003cli\u003eInsulated hot junction for reduction in electrical interference\u003c\/li\u003e\n\u003cli\u003ePlain pot seal with a temperature rating of 200°C.\u003c\/li\u003e\n\u003cli\u003ePFA insulated lead for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories. These thermocouples are particularly suitable for high pressure and vacuum applications, and able to withstand high levels of vibration.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003ePot seal maximum temperature is limited to 180°C\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable style=\"border-collapse:collapse;border-color:#ccc;border-spacing:0\" class=\"tg\"\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth style=\"background-color:#f0f0f0;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:18px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:bottom;word-break:normal\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eRS PRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e397-1264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eThermocouple Type\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eMineral Insulated Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProbe Material\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eStandards\/Approvals\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eIEC,  RoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eStandards Met\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161593098274,"sku":"3971264","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3971264-01_13043d42-018f-4bfe-b186-d26d479db9b4.webp?v=1792099210"},{"product_id":"rs-pro-3630294","title":"RS PRO Type K Thermocouple 2m Length, 1\/0.2mm Diameter, -60°C → +350°C;  363-0294","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K IEC Fine Wire Glassfibre Insulated Thermocouple with Miniature Plug Termination\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a type K fine wire thermocouple temperature sensor that conforms to IEC 584-3 class 2 standards. This bare wire thermocouple temperature sensor has a durable construction along with a welded exposed junction for a fast response time. One end of this thermocouple is terminated with an IEC 584 colour coded miniature flat pin plug. The flat pair cable has 1\/0.315 mm conductors and is insulated with durable silicone varnished glassfibre\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes. A thermocouple consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple has a welded exposed junction when the wires are welded together but are not surrounded by an outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eProperties of Glassfibre Insulation?\u003c\/h3\u003e\n\u003cp\u003eGlassfibre wire insulation is flexible with a good temperature range but does not prevent the ingress of fluids\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eGlassfibre insulated flat pair cable for wide temperature range\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 584-3 class 2\u003c\/li\u003e\n\u003cli\u003eMiniature IEC flat pin plug termination for quick and easy connection\u003c\/li\u003e\n\u003cli\u003eTemperature range of -60 to +350°C (short periods up to 400°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe K-Type thermocouple (Nickel-Chromium \/ Nickel-Alumel) the most common type of thermocouple and is both accurate and flexible and reliable with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, flues and in the glass industry\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:363-0294\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3208\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e1\/0.2mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e2m\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+350°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eMiniature Plug\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161605484578,"sku":"3630294","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3630294-01_b754f4fe-186b-4720-a631-134bb1384075.webp?v=1792099225"},{"product_id":"rs-pro-2287467","title":"RS PRO Type K Thermocouple 150mm Length, 3mm Diameter, 0°C → 1100°C;  228-7467","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Mineral Insulated Type K Thermocouple with Threaded Pot and Tails\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K thermocouple temperature sensors or probes that conform to IEC 584 specifications. These thermocouple temperature probes have durable construction with a 310 stainless steel mineral insulated flexible probe sheath that can be bent and formed to suit a wide range of applications. The thermocouple has a single element insulated hot junction for a reduction in electrical interference and a M8 x 1.00 mm fine pitch threaded pot seal with a temperature rating of 200°C.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is Mineral Insulation?\u003c\/h3\u003e\n\u003cp\u003eMineral insulation is used to insulate the thermocouple wires from one another and from the metal probe sheath that surrounds them. The sheath is filled with a highly compacted magnesium oxide powder that prevents the conductors from making contact with one another other than at the fixed junction. The high density of the mineral powder enables the thermocouple to have a rapid response as it promotes a fast heat transfer between the conductor and the sheath. Mineral insulation also helps to protect the thermocouple wire from environmental damage including corrosion, prevents electrical interference and allows the cable to be flexible whilst maintaining its mechanical strength\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsulated hot junction for reduced electrical interference\u003c\/li\u003e\n\u003cli\u003eMineral insulation for flexibility, durability and high performance\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eFlexible, can be bent into shape for easy installation\u003c\/li\u003e\n\u003cli\u003e310 stainless steel sheath for resistance to corrosion and oxidation\u003c\/li\u003e\n\u003cli\u003eM8 x 1.0 mm fine pitch threaded pot seal\u003c\/li\u003e\n\u003cli\u003eWide temperature range of -100 to +1100°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eM8 lock nuts are available, please see stock numbers 762-1162 and 762-1187\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161606533154,"sku":"2287467","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F2287467-01_e246230d-c1e9-42f3-a680-40cb7936ee74.webp?v=1792099227"},{"product_id":"rs-pro-2905036","title":"RS PRO Type K Thermocouple 40mm Length, 1\/0.2mm Diameter, -50°C → +150°C;  290-5036","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Type K Silicone Patch Thermocouple with Miniature Plug\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro an IEC standard Type K thermocouple temperature sensor designed for taking surface temperature measurements. The thermocouple lead is made from a 1 m length of twin-twist wire with a durable PFA insulation. One end of the lead is terminated with a miniature plug for a quick and easy connection. The other end is terminated with a 40 x 15 mm aluminium foil backed self adhesive moulded silicone patch for attaching to a surface.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Surface Thermocouple?\u003c\/h3\u003e\n\u003cp\u003eThis thermocouple is designed for measuring the temperature on a surface. Most thermocouples have a sensing tip where there ends of the thermocouple wires are encased in sheaths or protection tubes which do not allow for measuring the temperature of a surface area. Surface temperature sensing thermocouples overcome this problem by having the exposed welded wire junction housed in a magnet or adhesive patch. The patch or magnet is then securely attached to the surface to be measured to provide a true surface contact. This affixing method allows these thermocouples to be used on many types of surfaces including uneven and circular surfaces. They are also simple to use and easy to replace and position.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to IEC standards\u003c\/li\u003e\n\u003cli\u003eSelf adhesive silicone patch for accurate surface sensing\u003c\/li\u003e\n\u003cli\u003eMiniature plug for quick and easy connection\u003c\/li\u003e\n\u003cli\u003eDurable PFA insulated leads for resistance to oils, acids, fluids and for good mechanical strength and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1\/0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e40mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eAluminium Foil Backing, Silicone Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161646673954,"sku":"2905036","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F2905036-01_7f11dfe7-f83a-4031-91be-deaacab840c8.webp?v=1792099433"},{"product_id":"rs-pro-4094908","title":"RS PRO Type K Thermocouple Nickel Aluminium, Nickel Chrome probe 0.2mm Diameter, -100°C → +250°C;  409-4908","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K Fine Wire Thermocouple with Miniature Plug Termination\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K fine wire thermocouple temperature sensors with a Class 1 tolerance for optimum accuracy. These bare wire thermocouple temperature sensors have a durable construction with PTFE or glass fibre insulation. One end of the wire is terminated with a moulded plug that provides a quick and easy connection that is also waterproof. The exposed junctions of these Type K thermocouples means they have both increased sensitivity and a fast response time.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eA welded exposed junction is where the thermocouple wires are welded together but not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eClass 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eWaterproof plug for quick and easy termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese exposed junction K-Type fine wire thermocouples are ideal for test and development applications and are often used as embedded sensors for temperature measurement in the construction, paper, electronic and packaging industries.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eDurable PTFE Insulation for resistance to oils and acids, good mechanical strength and flexibility\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eNickel Aluminium, Nickel Chrome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161651261474,"sku":"4094908","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F4094908-01_8745728b-ea57-4b81-826a-70a1ee831526.webp?v=1792099440"},{"product_id":"rs-pro-2194674","title":"RS PRO Type T Thermocouple Stainless Steel probe 1.6mm Diameter, -100°C → +250°C;  219-4674","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS PRO Type T Thermocouple\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a high quality and great value Type T Thermocouple. This range of type T probes offers a fantastic solution in providing an economical means of measuring temperature. The body of this thermocouple is brazed to the probe and the 1.5m P.T.F.E. (Polytetrafluoroethylene) insulated cable passes through a waterproof entry.\u003c\/p\u003e\n\u003cp\u003eA thermocouple is a temperature sensor that has been engineered to measure the temperature of various types of components and substances. Out of the variety of thermocouple types that are available, this is a Type T which has a temperature range between −200 to +350°C and is noted for being especially stable.\u003c\/p\u003e\n\u003cp\u003eManufactured to be extremely robust with its thick wire and with its rigid 316 stainless steel needle probe with chisel pointed tip, this product proves to be an essential solution for measurement of temperature whilst also meeting standards in accordance with IEC (International Electrotechnical Commission).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eType T Temperature range of -75°C to +250°C,\u003c\/li\u003e\n\u003cli\u003eFast responding for quick readings,\u003c\/li\u003e\n\u003cli\u003eIdeal for use with semi-solid materials (food, plastics, rubber etc.),\u003c\/li\u003e\n\u003cli\u003eGrounded hot junction which is more robust than an exposed junction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThermocouples have a variety of applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMedical - research into DNA and hypodermic insertion to detecting a tumour.\u003c\/li\u003e\n\u003cli\u003eVehicle diagnostics - used to monitor and adjust factors such as battery health, exhaust readings, spark plug function and brake performance.\u003c\/li\u003e\n\u003cli\u003eTemperature readings in boilers, heating sensors, and ovens\u003c\/li\u003e\n\u003cli\u003eFood thermometers, industrial probes, and sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy choose RS Pro?\u003c\/h3\u003e\n\u003cp\u003eRS Pro is our own brand of high-quality products whilst bringing you great value for money. Our wide range of products have been engineered to meet high industry standards, so you are ensured reliable and robust solutions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1.6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161651327010,"sku":"2194674","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F2194674-01_df3dc684-9ce1-4361-9629-667c88c14a7b.webp?v=1792099440"},{"product_id":"rs-pro-2194545","title":"RS PRO Type K Thermocouple, -50°C → +100°C;  219-4545","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Type K Magnetic Strip Thermocouple with Miniature Plug\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro an IEC standard Type K thermocouple temperature sensor designed for taking surface temperature measurements. The thermocouple lead is made from a 2 m length of twin-twist wire with a durable PTFE insulation. One end of the lead is terminated with a miniature plug for a quick and easy connection. The other end is terminated with a 50 x 25 x 1 mm magnetic strip designed for attaching to most ferro-magnetic surfaces.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Surface Thermocouple?\u003c\/h3\u003e\n\u003cp\u003eThis thermocouple is designed for measuring the temperature on a surface. Most thermocouples have a sensing tip where there ends of the thermocouple wires are encased in sheaths or protection tubes which do not allow for measuring the temperature of a surface area. In surface temperature sensing thermocouples the exposed welded wire junction is housed in a magnet or adhesive patch which provides a true surface contact. This affixing method allows these thermocouples to be used on many types of surfaces including uneven and circular surfaces. They are also simple to use and easy to replace and position.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to IEC standards\u003c\/li\u003e\n\u003cli\u003eMagnetic strip for accurate surface sensing on metal surfaces\u003c\/li\u003e\n\u003cli\u003eMiniature plug for quick and easy connection\u003c\/li\u003e\n\u003cli\u003eDurable PTFE insulated leads for protection against oils, acids and other fluids and for good mechanical strngth and flexibility\u003c\/li\u003e\n\u003cli\u003eTemperature range of +50 to -100°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e50mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+100°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eMiniature Plug\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eCable Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e2m\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161651687458,"sku":"2194545","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F2194545-01_a16df351-999b-430b-9c3d-893e6b5f1b11.webp?v=1792099421"},{"product_id":"rs-pro-6212158","title":"RS PRO Type K Thermocouple 0.6mm Diameter, -50°C → +250°C;  621-2158","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC PTFE Grounded Welded Tip Wire Thermocoupless\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J, K, N and T wire type thermocouple temperature sensors that conform to IEC 60584. These thermocouples have a welded grounded junction for a fast response time and leads with a durable PTFE insulation\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWelded Grounded Junction\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded grounded junction with fast response\u003c\/li\u003e\n\u003cli\u003eConform to IEC 60584 standards\u003c\/li\u003e\n\u003cli\u003ePTFE insulated leads for for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese grounded junction Type J, K, N and T wire thermocouples are Ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eIEC-BS 4937 60584-2 \u0026amp; IEC-BS 4937 60584-3\u003c\/p\u003e\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cp\u003eType K welded tip\u003c\/p\u003e\n\u003cp\u003e1000 mm Length\u003c\/p\u003e\n\u003cp\u003e‐40°C to 375°C ±1.5°C\u003c\/p\u003e\n\u003cp\u003eSupplied in pack of 5\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e2mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e1m\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Material\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eTeflon PTFE\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+250°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161663844386,"sku":"6212158","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212158-01_325e5384-4ce3-464e-8edd-624f823c6040.webp?v=1792099444"},{"product_id":"rs-pro-6212237","title":"RS PRO Type J Thermocouple Stainless Steel probe 0.2mm Diameter, -50°C → +350°C;  621-2237","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type J IEC Thermocouple Probe with Leaf Termination\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a Type J thermocouple temperature sensor conforming to IEC 584 standards designed for connecting to a surface. This thermocouple has a robust design with a glass fibre insulated cable surrounded by a stainless steel braid. The cable is terminated with a stainless steel shim which allows the thermocouple to be welded or soldered into place on a flat surface. These thermocouples have a grounded hot junction for a fast response time\u003c\/p\u003e\n\u003ch3\u003eWhat is a Thermocouple?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Grounded Junction?\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eWhat is a Surface Thermocouple?\u003c\/h3\u003e\n\u003cp\u003eThis thermocouple is designed for measuring the temperature on a surface. Most thermocouples have a sensing tip where there ends of the thermocouple wires are encased in sheaths or protection tubes which do not allow for measuring the temperature of a surface area. In surface temperature sensing thermocouples the exposed welded wire junction is housed in a magnet or adhesive patch or, in this case terminated on to a stainless steel shim or 'leaf'. which provides a true surface contact.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeets IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eDurable glass fibre insulated cable with stainless steel braid\u003c\/li\u003e\n\u003cli\u003eGrounded hot junction for fast response time\u003c\/li\u003e\n\u003cli\u003eStainless steel 25 x 13 x 0.15 mm leaf termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis Type J leaf thermocouple is ideal for use in applications where low profile temperature detection is required and is commonly used for fitting under band or nozzle heaters\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161667317794,"sku":"6212237","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212237-01_1013aa07-af0d-430e-829e-789c86e206bd.webp?v=1792099425"},{"product_id":"rs-pro-7621128","title":"RS PRO Type K Thermocouple 150mm Length, 4.5mm Diameter, -60°C → 350°C;  762-1128","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K \u0026amp; Type J IEC Heavy Duty Glassfibre Insulated Thermocouple Probes\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K and Type J thermocouple probes with a rugged construction that conform to IEC 584 standards. These thermocouple temperature probes have a 150 mm long, 4.5 mm diameter stainless steel probe sheath for protection against corrosion. The cable has a durable design with glassfibre insulation surrounded by a stainless steel overbraid. These thermocouples have a grounded hot junction which enables them to have a fast response time\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes. A thermocouple consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Grounded Junction?\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged stainless steel probe sheath for protection against corrosion\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eWelded, grounded junction for fast response times\u003c\/li\u003e\n\u003cli\u003eRugged glassfibre insulated cable with stainless steel overbraid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003cp\u003eType J Thermocouples (Iron-Constantan) have a smaller temperature range and a shorter lifespan at higher temperatures than the Type K but has the same reliability. Type J thermocouples are ideal for monitoring the temperatures of inert materials and in vacuum applications. Applications include heat processes such as the manufacturing of plastic and resin and in electrical furnaces\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e4.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161676984354,"sku":"7621128","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F7621128-01_ce5f892b-8058-4eb9-996a-275999e3ec7f.webp?v=1792099442"},{"product_id":"rs-pro-8479681","title":"RS PRO Type T Thermocouple 1m Length, 1\/0.3mm Diameter, -75°C → +250°C;  847-9681","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro ANSI Type K \u0026amp; T Fine Wire Exposed Junction Thermocouples\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type K and Type T fine wire temperature sensing thermocouples ithat meet ANSI MC96.1 stanards with class 1 tolerance for optimum accuracy. These Type K and type T wire temperature sensors consist of a durable Teflon PFA insulated twin-twisted lead and a single element exposed welded junction for a fast response time.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eA welded exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eANSI MC96.1 class 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eClass 1 cable specification in accordance with BS EN 60584-3:2008\u003c\/li\u003e\n\u003cli\u003eExposed welded junction for fast response\u003c\/li\u003e\n\u003cli\u003eDurable Teflon PFA insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003cli\u003eTemperature ranges from -75 to +250°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese K Type and T type fine wire thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1\/0.3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eANSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161712930850,"sku":"8479681","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F8479681-01_53ccb285-0dcf-4da4-b554-84d70c2e2600.webp?v=1792099437"},{"product_id":"rs-pro-6212170","title":"RS PRO Type K Thermocouple 0.3mm Diameter, -50°C → +400°C;  621-2170","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Glassfibre IEC Exposed Welded Tip Thermocouples\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J, K, T \u0026amp; N wire type thermocouple temperature sensors conforming to IEC 60584 standards. These thermocouples have a welded exposed hot junction for a fast response time and cable conductors surrounded by a glassfibre insulation.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eAn exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eProperties of Glassfibre Insulation\u003c\/h3\u003e\n\u003cp\u003eGlassfibre wire insulation is flexible with a good temperature range but does not prevent the ingress of fluids\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eGlassfibre insulated cable for good flexibility and temperature range\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 60584 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese grounded junction Type J, K, T \u0026amp; N wire thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161718337570,"sku":"6212170","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212170-01_0c1bd78d-6f5f-4606-b07d-a82d65e108f3.webp?v=1792099621"},{"product_id":"rs-pro-6212209","title":"RS PRO Type T Thermocouple 0.3mm Diameter, -200°C → +350°C;  621-2209","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Glassfibre IEC Exposed Welded Tip Thermocouples\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J, K, T \u0026amp; N wire type thermocouple temperature sensors conforming to IEC 60584 standards. These thermocouples have a welded exposed hot junction for a fast response time and cable conductors surrounded by a glassfibre insulation.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eAn exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eProperties of Glassfibre Insulation\u003c\/h3\u003e\n\u003cp\u003eGlassfibre wire insulation is flexible with a good temperature range but does not prevent the ingress of fluids\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eGlassfibre insulated cable for good flexibility and temperature range\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 60584 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese grounded junction Type J, K, T \u0026amp; N wire thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cp\u003eType T welded tip\u003c\/p\u003e\n\u003cp\u003e2000 mm Length\u003c\/p\u003e\n\u003cp\u003e‐40°C to 120°C ±1.5°C\u003c\/p\u003e\n\u003cp\u003e2 cable 0.07 mm² CSA\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e0.3mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e2m\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+350°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eCable\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161718665250,"sku":"6212209","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212209-01_cad833dc-c1e6-4768-89d3-d95363576275.webp?v=1792099622"},{"product_id":"fluke-2098714-4723319","title":"Fluke Type K Thermocouple 203.2mm Length, 4.8mm diameter, -40°C → +816°C [2098714];  472-3319","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eTemperature probes for digital thermometers\u003c\/h3\u003e\n\u003cp\u003eThese probes are suited for use with numerous types of digital thermometers.\u003c\/p\u003e\n\u003cp\u003eAvailable in calibrated version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eThermocouple Type\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eK\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e4.8mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e203.2mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+816°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eMiniature Plug\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":32161719484450,"sku":"4723319","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/products\/F4723319-01.jpg?v=1593736723"},{"product_id":"rs-pro-4791788","title":"RS PRO Type K Thermocouple 3m Length, 1\/0.3mm Diameter, -100°C → +250°C;  479-1788","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K Fine Wire Thermocouple with Miniature Plug Termination\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K fine wire thermocouple temperature sensors with a Class 1 tolerance for optimum accuracy. These bare wire thermocouple temperature sensors have a durable construction with PTFE or glass fibre insulation. One end of the wire is terminated with a moulded plug that provides a quick and easy connection that is also waterproof. The exposed junctions of these Type K thermocouples means they have both increased sensitivity and a fast response time.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eA welded exposed junction is where the thermocouple wires are welded together but not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eClass 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eWaterproof plug for quick and easy termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese exposed junction K-Type fine wire thermocouples are ideal for test and development applications and are often used as embedded sensors for temperature measurement in the construction, paper, electronic and packaging industries.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eDurable PTFE Insulation for resistance to oils and acids, good mechanical strength and flexibility\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e1\/0.3mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e3m\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+250°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eMiniature Plug\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161744715810,"sku":"4791788","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F4791788-01_f4b9f40b-6d86-4fa6-876a-7cf512c79fb5.webp?v=1792099627"},{"product_id":"rs-pro-259334","title":"RS PRO Type K Thermocouple 170mm Length, 6mm Diameter, 0°C → 400°C;  259-334","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type J and K IEC Thermocouples with Adjustable Bayonet Probe\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J and Type K thermocouple temperature sensors conforming to IEC 584 standards with a grounded hot junction for a fast response time. These durable type J and Type K thermocouples have a 2 m long cable with flexible glass fibre insulation and a rugged stainless steel braid. The probe has a stainless steel sheath which is surrounded by an adjustable spring loaded bayonet connector which enables the thermocouple to fitted securely\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Grounded Junction?\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eWhat is an Adjustable Bayonet Probe?\u003c\/h3\u003e\n\u003cp\u003eThe probes of these thermocouple sensors have an adjustable screw threaded spring 175 mm long with a slotted bayonet fixing cap. The bayonet cap screws along this spring and allows the immersion length of the thermocouple probe to be adjusted. Once in place the bayonet cap is secured to a bayonet adapter (which must be purchased separately - see stock number 621-2243) allowing the thermocouple to be firmly held in place within the recess. The advantages of this method of fixing are;\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImmersion depth can be adjusted easily\u003c\/li\u003e\n\u003cli\u003eSecure connection within machine recess\u003c\/li\u003e\n\u003cli\u003ePositive pressure at the thermocouple tip and full immersion in process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to IEC 584 Standards\u003c\/li\u003e\n\u003cli\u003eAdjustable spring loaded bayonet connection\u003c\/li\u003e\n\u003cli\u003eGrounded hot junction for fast response time\u003c\/li\u003e\n\u003cli\u003eRugged glass fibre insulated cable with stainless steel overbraid\u003c\/li\u003e\n\u003cli\u003eStainless steel probe sheath for resistance to corrosion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStandard tolerence TC \"K\" class1:\u003c\/p\u003e\n\u003cp\u003e‐40°C \u0026lt; t°\u0026lt; 375°C = ± 1.5°C\u003c\/p\u003e\n\u003cp\u003e375°C \u0026lt; t°\u0026lt; 1000°C= ±0.004. [t]\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003ehese J-Type and K-Type thermocouple temperature sensors are designed for direct installation into the process. The bayonet fitting makes them suited for applications where the thermocouple sensor tip is fitted directly into a drilled hole or recess in machinery. Typical applications include the plastics and rubber industry where they are used in extrusion and moulding machinery\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e170mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161749631010,"sku":"259334","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F0259334-01_8dc4fad6-f501-4926-94f1-2f207d73ef1b.webp?v=1792099638"},{"product_id":"rs-pro-2194371","title":"RS PRO Type K Thermocouple 1m Length, 1.5mm Diameter, 0°C → +1100°C;  219-4371","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Mineral Insulated Type K Thermocouple with Threaded Pot and Tails\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K thermocouple temperature sensors or probes that conform to IEC 584 specifications. These thermocouple temperature probes have durable construction with a 310 stainless steel mineral insulated flexible probe sheath that can be bent and formed to suit a wide range of applications. The thermocouple has a single element insulated hot junction for a reduction in electrical interference and a M8 x 1.00 mm fine pitch threaded pot seal with a temperature rating of 200°C.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is Mineral Insulation?\u003c\/h3\u003e\n\u003cp\u003eMineral insulation is used to insulate the thermocouple wires from one another and from the metal probe sheath that surrounds them. The sheath is filled with a highly compacted magnesium oxide powder that prevents the conductors from making contact with one another other than at the fixed junction. The high density of the mineral powder enables the thermocouple to have a rapid response as it promotes a fast heat transfer between the conductor and the sheath. Mineral insulation also helps to protect the thermocouple wire from environmental damage including corrosion, prevents electrical interference and allows the cable to be flexible whilst maintaining its mechanical strength\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsulated hot junction for reduced electrical interference\u003c\/li\u003e\n\u003cli\u003eMineral insulation for flexibility, durability and high performance\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eFlexible, can be bent into shape for easy installation\u003c\/li\u003e\n\u003cli\u003e310 stainless steel sheath for resistance to corrosion and oxidation\u003c\/li\u003e\n\u003cli\u003eM8 x 1.0 mm fine pitch threaded pot seal\u003c\/li\u003e\n\u003cli\u003eWide temperature range of -100 to +1100°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eM8 lock nuts are available, please see stock numbers 762-1162 and 762-1187\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:219-4371\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3263\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e1.5mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e1m\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Material\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eStainless Steel\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+1100°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161837842466,"sku":"2194371","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F2194371-01_5f9dceaa-5f63-41a3-bd9a-e55481d733cd.webp?v=1792099831"},{"product_id":"jumo-901240-20-1040-3-1000-000-5488562","title":"Jumo Type J Thermocouple 1m Length, 3mm diameter, -200°C → +800°C [901240\/20-1040-3-1000\/000];  548-8562","description":"\u003cstyle type=\"text\/css\"\u003e@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable style=\"border-collapse:collapse;border-color:#ccc;border-spacing:0\" class=\"tg\"\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth style=\"background-color:#f0f0f0;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:18px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:bottom;word-break:normal\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eJumo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e901240\/20-1040-3-1000\/000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eThermocouple Type\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e+800°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eTermination Type\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eGiá: \u003cstrong\u003eLiên hệ\u003c\/strong\u003e – gửi mã và số lượng về CV@chanhvinh.com để nhận báo giá nhanh.\u003c\/p\u003e","brand":"JUMO","offers":[{"title":"Default Title","offer_id":32161838039074,"sku":"5488562","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/products\/RF548829-10.jpg?v=1593740912"},{"product_id":"rs-pro-1236332","title":"RS PRO Type T Thermocouple, -75°C → +250°C;  123-6332","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eDurable Type K, J \u0026amp; T Exposed Welded Tip Thermocouples\u003c\/h3\u003e\n\u003cp\u003eVarious types of exposed junction thermocouples with fitted miniature plug and insulated leads, ideal for test and develoment applications.\u003c\/p\u003e\n\u003cp\u003eThermocouple types K, J \u0026amp; T to IEC 584\u003c\/p\u003e\n\u003cp\u003eFast response, welded exposed junction\u003c\/p\u003e\n\u003cp\u003eDurable Teflon construction with choice of conductor size, 1\/0.315mm solid or 7\/0.2mm stranded\u003c\/p\u003e\n\u003cp\u003eMiniature plug termination\u003c\/p\u003e\n\u003cp\u003eTemperature range -75 → +250 °C\u003c\/p\u003e\n\u003cp\u003eIdeal for test \u0026amp; development applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161853079586,"sku":"1236332","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F1236332-01_fe2c378f-48f9-46ab-95d8-33be97d3dc6f.webp?v=1792099831"},{"product_id":"rs-pro-4094920","title":"RS PRO Type K Thermocouple Nickel Aluminium, Nickel Chrome probe 1.2mm Diameter, -100°C → +450°C;  409-4920","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K Fine Wire Thermocouple with Miniature Plug Termination\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K fine wire thermocouple temperature sensors with a Class 1 tolerance for optimum accuracy. These bare wire thermocouple temperature sensors have a durable construction with PTFE or glass fibre insulation. One end of the wire is terminated with a moulded plug that provides a quick and easy connection that is also waterproof. The exposed junctions of these Type K thermocouples means they have both increased sensitivity and a fast response time.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eA welded exposed junction is where the thermocouple wires are welded together but not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eClass 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eWaterproof plug for quick and easy termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese exposed junction K-Type fine wire thermocouples are ideal for test and development applications and are often used as embedded sensors for temperature measurement in the construction, paper, electronic and packaging industries.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eDurable glass fibre insulation for flexibility and a wide temperature range\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+450°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eNickel Aluminium, Nickel Chrome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161877950498,"sku":"4094920","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F4094920-01_81e25ae0-9f1e-40b6-b3db-a7d1bc73122b.webp?v=1792099839"},{"product_id":"rs-pro-6212142","title":"RS PRO Type J Thermocouple 0.2mm Diameter, -50°C → +250°C;  621-2142","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC PTFE Grounded Welded Tip Wire Thermocoupless\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J, K, N and T wire type thermocouple temperature sensors that conform to IEC 60584. These thermocouples have a welded grounded junction for a fast response time and leads with a durable PTFE insulation\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWelded Grounded Junction\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded grounded junction with fast response\u003c\/li\u003e\n\u003cli\u003eConform to IEC 60584 standards\u003c\/li\u003e\n\u003cli\u003ePTFE insulated leads for for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese grounded junction Type J, K, N and T wire thermocouples are Ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eIEC-BS 4937 60584-2 \u0026amp; IEC-BS 4937 60584-3\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e2mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e1m\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+250°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Material\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eTeflon PTFE\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32161963900962,"sku":"6212142","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212142-01_c4c3f016-9635-4c3e-99ae-e902a646b55b.webp?v=1792100057"},{"product_id":"rs-pro-158626","title":"RS PRO Type K Thermocouple 1m Length, 7mm Diameter, 0°C → +200°C;  158-626","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-vox4{font-size:16px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-2e5m{background-color:#D2E4FC;font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-bbej{background-color:#D2E4FC;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-na3a{font-size:14px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ltad{font-size:14px;text-align:left;vertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS PRO Type K Thermocouple 1 m Length, 7 mm Diameter +200°C\u003c\/h3\u003e\n\u003cp\u003eThis Type K thermocouple from RS PRO is used in industrial environments to measure extreme temperature ranges. It's made of Chromel and Alumel conductors joined at one end, which creates a voltage with every heat change that can be measured and correlated back to the temperature. These conductors are covered by Teflon insulated twisted wire to protect you from electrical shock due to short circuits.\u003c\/p\u003e\n\u003cp\u003eThis thermocouple has great mechanical strength which means it can withstand impact, so it's ideal for most outdoor applications. It also has great resistance to oils, acids and other adverse fluids so it can be used in heavy-duty industrial environments. With an operating temperature range of between 0°C and +200°C, you can use this sensor in harsh climes. It's ideal for testing and development applications in various sectors, such as the petroleum, chemical and oil and gas industries.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable length of 1 m\u003c\/li\u003e\n\u003cli\u003eMaximum sensed temperature of +200°C\u003c\/li\u003e\n\u003cli\u003eProbe diameter of 7 mm\u003c\/li\u003e\n\u003cli\u003eProbe length of 1 m\u003c\/li\u003e\n\u003cli\u003eCopper probe material\u003c\/li\u003e\n\u003cli\u003eMeets British Standards (BS) BS1843\u003c\/li\u003e\n\u003cli\u003eCable termination type\u003c\/li\u003e\n\u003cli\u003eType K thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:158-626\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3190\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-vox4\" colspan=\"2\"\u003e.THÔNG SỐ KỸ THUẬT:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e7mm\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Length\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e1m\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eProbe Material\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003eCopper\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\n\u003ctd class=\"tg-2e5m\"\u003eMaximum Temperature Sensed\u003c\/td\u003e\n\u003ctd class=\"tg-bbej\"\u003e+200°C\u003c\/td\u003e \n\u003c\/tr\u003e \n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162013151266,"sku":"158626","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F0158626-01_4d0b7c22-af84-439e-a82d-2c5aca6c4e9e.webp?v=1792100037"},{"product_id":"rs-pro-7877734","title":"RS PRO Type K Thermocouple 500mm Length, 3mm Diameter, -100°C → 1100°C;  787-7734","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K Mineral Insulated Thermocouples with Plain Pot Seal and Lead\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K thermocouple temperature sensors that conform to IEC 584 standards with class 1 tolerance for optimum accuracy. These sensors or probes have a durable construction and feature a stainless steel 310 probe sheath and a PFA insulated lead. The mineral insulated flexible probe sheath can be bent and formed to suit a wide range of applications. The thermocouple has a single element insulated hot junction for a reduction in electrical interference and a plain pot seal with a temperature rating of 200°C.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is Mineral Insulation?\u003c\/h3\u003e\n\u003cp\u003eMineral insulation is used to insulate the thermocouple wires from one another and from the metal probe sheath that surrounds them. The sheath is filled with a highly compacted magnesium oxide powder that prevents the conductors from making contact with one another other than at the fixed junction. The high density of the mineral powder enables the thermocouple to have a rapid response as it promotes a fast heat transfer between the conductor and the sheath. Mineral insulation also helps to protect the thermocouple wire from environmental damage including corrosion, prevents electrical interference and allows the cable to be flexible whilst maintaining its mechanical strength\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDurable 310 stainless steel probe sheath for protection against corrosion and oxidation\u003c\/li\u003e\n\u003cli\u003eIEC 584 class 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eMineral insulation for flexibility, durability and high performance\u003c\/li\u003e\n\u003cli\u003eInsulated hot junction for reduction in electrical interference\u003c\/li\u003e\n\u003cli\u003ePlain pot seal with a temperature rating of 200°C.\u003c\/li\u003e\n\u003cli\u003ePFA insulated lead for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories. These thermocouples are particularly suitable for high pressure and vacuum applications, and able to withstand high levels of vibration.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003ePot seal maximum temperature is limited to 180°C\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162025930786,"sku":"7877734","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F7877734-01_8f8abcec-1685-4d0a-a45f-f9104dd164fe.webp?v=1792100048"},{"product_id":"rs-pro-6212259","title":"RS PRO Type J Thermocouple 2m Length, 0.2mm Diameter, -50°C → +400°C;  621-2259","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type J IEC Thermocouple Probe with Nozzle Termination\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a Type J thermocouple temperature sensor conforming to IEC 584 standards. This durable type J thermocouple has a 2 m long wire with glass fibre insulation and a stainless steel braid. The probe is housed in a stainless steel sheath and fitted with a nozzle and a threaded bolt. This thermocouple has a ungrounded hot junction for a reduction in electrical interference.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is a Nozzle Termination?\u003c\/h3\u003e\n\u003cp\u003eThis thermocouple probe has a nozzle at the end and a threaded bolt. The threaded bolt secures the thermocouple into a pre-determined threaded hole enabling the thermocouple to be mounted directly into the process. This method of connection allows the sensor to have a positive pressure at the sensing tip when it is installed\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeets IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eDurable glass fibre insulated cable with stainless steel braid\u003c\/li\u003e\n\u003cli\u003eStainless steel probe sheath for protection against corrosion\u003c\/li\u003e\n\u003cli\u003eInsulated hot junction for reduction in electrical interference\u003c\/li\u003e\n\u003cli\u003eNozzle and threaded bolt for secure connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis Type J nozzle end thermocouple is ideal for use in applications where low profile temperature detection is required. Due to its construction this thermocouple can be used in harsh environment areas where a good positive securing method is required. These thermocouples are commonly used in the plastics and rubber industry, applications include nozzle extensions and manifolds on injection moulding machines\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162030714914,"sku":"6212259","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212259-01_211aeaf6-4445-4407-8f61-56207e89399a.webp?v=1792100053"},{"product_id":"rs-pro-7877719","title":"RS PRO Type K Thermocouple 500mm Length, 1.5mm Diameter, -100°C → 1100°C; 787-7719","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K Mineral Insulated Thermocouples with Plain Pot Seal and Lead\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K thermocouple temperature sensors that conform to IEC 584 standards with class 1 tolerance for optimum accuracy. These sensors or probes have a durable construction and feature a stainless steel 310 probe sheath and a PFA insulated lead. The mineral insulated flexible probe sheath can be bent and formed to suit a wide range of applications. The thermocouple has a single element insulated hot junction for a reduction in electrical interference and a plain pot seal with a temperature rating of 200°C.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is Mineral Insulation?\u003c\/h3\u003e\n\u003cp\u003eMineral insulation is used to insulate the thermocouple wires from one another and from the metal probe sheath that surrounds them. The sheath is filled with a highly compacted magnesium oxide powder that prevents the conductors from making contact with one another other than at the fixed junction. The high density of the mineral powder enables the thermocouple to have a rapid response as it promotes a fast heat transfer between the conductor and the sheath. Mineral insulation also helps to protect the thermocouple wire from environmental damage including corrosion, prevents electrical interference and allows the cable to be flexible whilst maintaining its mechanical strength\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDurable 310 stainless steel probe sheath for protection against corrosion and oxidation\u003c\/li\u003e\n\u003cli\u003eIEC 584 class 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eMineral insulation for flexibility, durability and high performance\u003c\/li\u003e\n\u003cli\u003eInsulated hot junction for reduction in electrical interference\u003c\/li\u003e\n\u003cli\u003ePlain pot seal with a temperature rating of 200°C.\u003c\/li\u003e\n\u003cli\u003ePFA insulated lead for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories. These thermocouples are particularly suitable for high pressure and vacuum applications, and able to withstand high levels of vibration.\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003ePot seal maximum temperature is limited to 180°C\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:787-7719\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3272\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162058240034,"sku":"7877719","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F7877719-01.webp?v=1791620256"},{"product_id":"rs-pro-3971488","title":"RS PRO Type K Thermocouple 150mm Length, 3mm Diameter, 0°C → +1100°C; 397-1488","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Mineral Insulated Type K Thermocouple with Miniature Plug\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K thermocouple temperature sensors or probes that conform to IEC standards. These thermocouple temperature probes have a durable construction and feature a 310 stainless steel mineral insulated flexible sheath that can be bent and formed to suit a wide range of applications. The thermocouple has a single element insulated junction for a reduction in electrical interference. One end of the thermocouple is terminated with a miniature flat pin plug for a quick and easy connection\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is Mineral Insulation?\u003c\/h3\u003e\n\u003cp\u003eMineral insulation is used to insulate the thermocouple wires from one another and from the metal probe sheath that surrounds them. The sheath is filled with a highly compacted magnesium oxide powder that prevents the conductors from making contact with one another other than at the fixed junction. The high density of the mineral powder enables the thermocouple to have a rapid response as it promotes a fast heat transfer between the conductor and the sheath. Mineral insulation also helps to protect the thermocouple wire from environmental damage including corrosion, prevents electrical interference and allows the cable to be flexible whilst maintaining its mechanical strength\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsulated hot junction for reduced electrical interference\u003c\/li\u003e\n\u003cli\u003eMineral insulation for flexibility, durability and high performance\u003c\/li\u003e\n\u003cli\u003eConforms to IEC standards\u003c\/li\u003e\n\u003cli\u003eFlexible, can be bent into shape for easy installation\u003c\/li\u003e\n\u003cli\u003e310 stainless steel probe sheath for resistance to corrosion and oxidation\u003c\/li\u003e\n\u003cli\u003eMiniature plug termination for a quick and easy connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3268\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162091171874,"sku":"3971488","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3971488-01_6c25626d-d72f-4c65-9e72-46a265f5c44d.webp?v=1792100253"},{"product_id":"rs-pro-6212271","title":"RS PRO Type K Thermocouple Stainless Steel probe 6mm Diameter, -50°C → 350°C; 621-2271","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type J and Type K IEC Thermocouple Probes with Washer Termination\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro Type K and Type J thermocouple temperature sensors conforming to IEC 584 standards. These durable thermocouples have a rugged design with a 2 m long glass fibre insulated wire surrounded by a 316 stainless steel braid. The probe is terminated with a stainless steel washer with a 6 mm internal diameter for measuring surface temperatures. These thermocouple temperature sensors have a grounded hot junction for a fast response time\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Grounded Junction?\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eWhat is a Surface Thermocouple?\u003c\/h3\u003e\n\u003cp\u003eThis thermocouple is designed for measuring the temperature on a surface. Most thermocouples have a sensing tip where there ends of the thermocouple wires are encased in sheaths or protection tubes which do not allow for measuring the temperature of a surface area. In surface temperature sensing thermocouples the exposed welded wire junction is housed in a magnet, adhesive patch, washer or bolt which provides a true surface contact. These thermocouple sensors are easy to install and use, the washer at the end of the sensor is simply positioned under a bolt or a rivet\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeets IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eDurable glass fibre insulated cable with stainless steel braid\u003c\/li\u003e\n\u003cli\u003eGrounded hot junction for fast response time\u003c\/li\u003e\n\u003cli\u003eEasy to install washer termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese Type J and Type K washer terminated thermocouple sensors are ideal for use in applications where low profile temperature detection is required and is commonly used for surface or pipe measurement applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162101657634,"sku":"6212271","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212271-01_235d998a-f18c-4be9-86e7-603a9187e46a.webp?v=1792100266"},{"product_id":"rs-pro-8047874","title":"RS PRO Type K Thermocouple 5m Length, 1\/0.3mm Diameter, -60°C → +350°C; 804-7874","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K IEC Fine Wire Glassfibre Insulated Thermocouple with Miniature Plug Termination\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a type K fine wire thermocouple temperature sensor that conforms to IEC 584-3 class 2 standards. This bare wire thermocouple temperature sensor has a durable construction along with a welded exposed junction for a fast response time. One end of this thermocouple is terminated with an IEC 584 colour coded miniature flat pin plug. The flat pair cable has 1\/0.315 mm conductors and is insulated with durable silicone varnished glassfibre\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes. A thermocouple consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple has a welded exposed junction when the wires are welded together but are not surrounded by an outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eProperties of Glassfibre Insulation?\u003c\/h3\u003e\n\u003cp\u003eGlassfibre wire insulation is flexible with a good temperature range but does not prevent the ingress of fluids\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eGlassfibre insulated flat pair cable for wide temperature range\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 584-3 class 2\u003c\/li\u003e\n\u003cli\u003eMiniature IEC flat pin plug termination for quick and easy connection\u003c\/li\u003e\n\u003cli\u003eTemperature range of -60 to +350°C (short periods up to 400°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe K-Type thermocouple (Nickel-Chromium \/ Nickel-Alumel) the most common type of thermocouple and is both accurate and flexible and reliable with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, flues and in the glass industry\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:804-7874\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3213\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1\/0.3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162107359266,"sku":"8047874","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F8047874-01_1473c53f-017f-466a-96dc-26894c9cb714.webp?v=1792100272"},{"product_id":"rs-pro-1236320","title":"RS PRO Type K Thermocouple 7\/0.2mm Diameter, -75°C → +250°C; 123-6320","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eDurable Type K, J \u0026amp; T Exposed Welded Tip Thermocouples\u003c\/h3\u003e\n\u003cp\u003eVarious types of exposed junction thermocouples with fitted miniature plug and insulated leads, ideal for test and develoment applications.\u003c\/p\u003e\n\u003cp\u003eThermocouple types K, J \u0026amp; T to IEC 584\u003c\/p\u003e\n\u003cp\u003eFast response, welded exposed junction\u003c\/p\u003e\n\u003cp\u003eDurable Teflon construction with choice of conductor size, 1\/0.315mm solid or 7\/0.2mm stranded\u003c\/p\u003e\n\u003cp\u003eMiniature plug termination\u003c\/p\u003e\n\u003cp\u003eTemperature range -75 → +250 °C\u003c\/p\u003e\n\u003cp\u003eIdeal for test \u0026amp; development applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e7\/0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162266513442,"sku":"1236320","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F1236320-01_09f87cac-9ae8-46a2-b2f0-ae2422d21423.webp?v=1792100268"},{"product_id":"rs-pro-3971589","title":"RS PRO Type K Thermocouple 0.075mm Diameter, -75°C → +250°C; 397-1589","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro ANSI Type K Fine Gauge Exposed Welded Tip Thermocouples\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K fine gauge wire thermocouple temperature sensors conforming to ANSI standards. These thermocouple temperature sensors feature a welded tip exposed junction for a fast response time. The lead consists of 0.0076 mm conductors with durable Teflon PFA insulation colour coded to ANSI specifications\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eAn exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eDurable PFA insulated leads for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003cli\u003eConforms to ANSI standards\u003c\/li\u003e\n\u003cli\u003eTemperature range of -75 to +260°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese Type K fine wire gauge thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:397-1589\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3210\u003c\/p\u003e\n\u003cp\u003eFine Gauge\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.075mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eANSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162380906530,"sku":"3971589","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3971589-01_afa169d8-7460-4f72-a2fa-9996221354bb.webp?v=1792100273"},{"product_id":"rs-pro-3971539","title":"RS PRO Type K Thermocouple 150mm Length, 3mm Diameter, 0°C → +1100°C; 397-1539","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K IEC Thermocouple Probes with Standard Plug Termination, Ungrounded\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type K thermocouple temperature sensing probes that conform to IEC 584-1 \u0026amp; 2 standards with a fast response time and a durable construction. These Type K thermocouple probes feature a stainless steel 310 sheath and are terminated with a standard IEC round pinned plug for a quick and simple connection. The sheath of the probe is mineral insulated making it flexible, allowing it to be bent and formed to suit a wide range of applications. The thermocouple has a single element grounded hot junction for a reduction in electrical interference\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is Mineral Insulation?\u003c\/h3\u003e\n\u003cp\u003eMineral insulation is used to insulate the thermocouple wires from one another and from the metal probe sheath that surrounds them. The sheath is filled with a highly compacted magnesium oxide powder that prevents the conductors from making contact with one another other than at the fixed junction. The high density of the mineral powder enables the thermocouple to have a rapid response as it promotes a fast heat transfer between the conductor and the sheath. Mineral insulation also helps to protect the thermocouple wire from environmental damage including corrosion, prevents electrical interference and allows the cable to be flexible whilst maintaining its mechanical strength\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDurable 310 stainless steel sheath for protection against corrosion and oxidation\u003c\/li\u003e\n\u003cli\u003eMeets IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eIEC colour coded standard plug for quick and easy connection\u003c\/li\u003e\n\u003cli\u003eMineral insulation for flexibility, durability and high performance\u003c\/li\u003e\n\u003cli\u003e0.5 mm probe diameter\u003c\/li\u003e\n\u003cli\u003eInsulated hot junction for reduction in electrical interference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStandard Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162417377314,"sku":"3971539","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3971539-01_f05398eb-1c1b-43de-9dc3-c596f192d108.webp?v=1792100259"},{"product_id":"rs-pro-3630323","title":"RS PRO Type K Thermocouple 1m Length, 1\/0.2mm Diameter, -75°C → +250°C; 363-0323","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Type K Exposed Junction Fast Response Thermocouple with Moulded Miniature Plug\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K thermocouple temperature sensors conforming to IEC-584-3 standards with a Class 1 tolerance. These thermocouple temperature sensors feature a welded tip exposed junction for a fast response time. The twin-twisted leads have a durable Teflon PFA insulation and are terminated one end with a moulded miniature flat pin plug which is colour coded green in accordance with IEC. The moulded plug has a a robust construction, provides a waterproof termination and enables a quick and easy connection.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eA welded exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eIEC-584-3 Class 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eDurable Teflon PFA lead insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003cli\u003eMiniature moulded plug with robust design for quick connection and waterproof termination\u003c\/li\u003e\n\u003cli\u003eTemperature range of -75 to +250°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eExposed junction thermocouples are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Applications include test and development, test and measurement, temperature mapping and OEM applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1\/0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162502443042,"sku":"3630323","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3630323-01_434f947b-fee1-4218-9b8d-d6f649144303.webp?v=1792100460"},{"product_id":"rs-pro-3971573","title":"RS PRO Type K Thermocouple 200mm Length, 0.025mm Diameter; 397-1573","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS PRO Type K Thermocouple 200 mm Length, 0.025 mm Diameter\u003c\/h3\u003e\n\u003cp\u003eThis RS PRO Type K thermocouple has a high level of sensitivity for fast and precise temperature measurement. The bare wire junction, welded tip and 0.025 mm ultra-fine gauge wire leads all promote a fast thermal reaction, giving you results in a fraction of a second. This combination of sensitivity and speed leads to an exceptionally high level of accuracy in your readings, as the thermocouple is able to quickly measure changing temperatures.\u003c\/p\u003e\n\u003cp\u003eThis type of bare-wire thermocouple is especially suited for use in situations where minimal invasive temperature sensing is required. It's commonly used for applications such as testing and development, temperature mapping and OEM (original equipment manufacturer) applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable length of 200 mm\u003c\/li\u003e\n\u003cli\u003eProbe diameter of 0.025 mm\u003c\/li\u003e\n\u003cli\u003eProbe length of 200 mm\u003c\/li\u003e\n\u003cli\u003eIEC (International Electrotechnical Commission) compliant\u003c\/li\u003e\n\u003cli\u003eCable termination type\u003c\/li\u003e\n\u003cli\u003eType K thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.025mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162616573986,"sku":"3971573","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3971573-01_08bfd256-3cf1-4d31-997f-09c3355f023a.webp?v=1792100472"},{"product_id":"rs-pro-6212164","title":"RS PRO Type T Thermocouple 0.2mm Diameter, -200°C → +350°C; 621-2164","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC PTFE Grounded Welded Tip Wire Thermocoupless\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J, K, N and T wire type thermocouple temperature sensors that conform to IEC 60584. These thermocouples have a welded grounded junction for a fast response time and leads with a durable PTFE insulation\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWelded Grounded Junction\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded grounded junction with fast response\u003c\/li\u003e\n\u003cli\u003eConform to IEC 60584 standards\u003c\/li\u003e\n\u003cli\u003ePTFE insulated leads for for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese grounded junction Type J, K, N and T wire thermocouples are Ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eIEC-BS 4937 60584-2 \u0026amp; IEC-BS 4937 60584-3\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eTeflon PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162661728290,"sku":"6212164","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212164-01_b52976fc-33e0-406d-8242-b3ca453e8e88.webp?v=1792100468"},{"product_id":"fluke-80pk-24-4711833","title":"Fluke Type K Thermocouple 215.9mm Length, 3.175mm diameter, -40°C → 816°C [80PK-24]; 471-1833","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eTemperature probes for digital thermometers\u003c\/h3\u003e\n\u003cp\u003eThese probes are suited for use with numerous types of digital thermometers.\u003c\/p\u003e\n\u003cp\u003eAvailable in calibrated version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e3.175mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e215.9mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+816°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":32162704031778,"sku":"4711833","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/products\/RD471183-01.jpg?v=1593749612"},{"product_id":"rs-pro-6212293","title":"RS PRO Type K Thermocouple 13 → 20mm Diameter, -50°C → +1100°C; 621-2293","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS PRO type K thermocouple pipe\u003c\/h3\u003e\n\u003cp\u003eFrom RS PRO, comes a range type K thermocouple pipes. Manufactured with high-quality stainless steel, these great value thermocouples are a fantastic solution for temperature measurement.\u003c\/p\u003e\n\u003ch3\u003eFeatures and benefits:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum operating temperatures of +1100 °C.\u003c\/li\u003e\n\u003cli\u003eMeets RoHS (Restriction of Hazardous Substances) standards\u003c\/li\u003e\n\u003cli\u003evarious probe diameters available in this range.\u003c\/li\u003e\n\u003cli\u003eFast response time of 0.7s\u003c\/li\u003e\n\u003cli\u003eGlass fibre insulated wire for added flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThermocouples have a variety of applications such as;\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMedical - research into DNA and hypodermic insertion to detecting a tumour.\u003c\/li\u003e\n\u003cli\u003eVehicle diagnostics - used to monitor and adjust factors such as battery health, exhaust readings, spark plug function and brake performance.\u003c\/li\u003e\n\u003cli\u003eTemperature readings in boilers, heating sensors, and ovens\u003c\/li\u003e\n\u003cli\u003eFood thermometers, industrial probes, and sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat are type K thermocouple sensors?\u003c\/h3\u003e\n\u003cp\u003eType K sensors, which typically have a temperature range from -200 to +1260°C, are known to be commonly used in a variety of industries and sectors. Type K sensors are also very accurate and reliable across wide ranges of operating temperatures.\u003c\/p\u003e\n\u003ch3\u003eWhy choose RS PRO?\u003c\/h3\u003e\n\u003cp\u003eRS PRO is our own brand of high-quality products whilst bringing you great value for money. Our wide range of products have been engineered to meet high industry standards, so you are ensured reliable and robust solutions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e13 → 20mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162735161378,"sku":"6212293","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212293-01_68614e71-e6e3-41b4-9c5d-21a21759aa63.webp?v=1792100459"},{"product_id":"rs-pro-259328","title":"RS PRO Type J Thermocouple 170mm Length, 6mm Diameter, 0°C → +350°C; 259-328","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type J and K IEC Thermocouples with Adjustable Bayonet Probe\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J and Type K thermocouple temperature sensors conforming to IEC 584 standards with a grounded hot junction for a fast response time. These durable type J and Type K thermocouples have a 2 m long cable with flexible glass fibre insulation and a rugged stainless steel braid. The probe has a stainless steel sheath which is surrounded by an adjustable spring loaded bayonet connector which enables the thermocouple to fitted securely\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Grounded Junction?\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eWhat is an Adjustable Bayonet Probe?\u003c\/h3\u003e\n\u003cp\u003eThe probes of these thermocouple sensors have an adjustable screw threaded spring 175 mm long with a slotted bayonet fixing cap. The bayonet cap screws along this spring and allows the immersion length of the thermocouple probe to be adjusted. Once in place the bayonet cap is secured to a bayonet adapter (which must be purchased separately - see stock number 621-2243) allowing the thermocouple to be firmly held in place within the recess. The advantages of this method of fixing are;\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImmersion depth can be adjusted easily\u003c\/li\u003e\n\u003cli\u003eSecure connection within machine recess\u003c\/li\u003e\n\u003cli\u003ePositive pressure at the thermocouple tip and full immersion in process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to IEC 584 Standards\u003c\/li\u003e\n\u003cli\u003eAdjustable spring loaded bayonet connection\u003c\/li\u003e\n\u003cli\u003eGrounded hot junction for fast response time\u003c\/li\u003e\n\u003cli\u003eRugged glass fibre insulated cable with stainless steel overbraid\u003c\/li\u003e\n\u003cli\u003eStainless steel probe sheath for resistance to corrosion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStandard tolerence TC \"K\" class1:\u003c\/p\u003e\n\u003cp\u003e‐40°C \u0026lt; t°\u0026lt; 375°C = ± 1.5°C\u003c\/p\u003e\n\u003cp\u003e375°C \u0026lt; t°\u0026lt; 1000°C= ±0.004. [t]\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003ehese J-Type and K-Type thermocouple temperature sensors are designed for direct installation into the process. The bayonet fitting makes them suited for applications where the thermocouple sensor tip is fitted directly into a drilled hole or recess in machinery. Typical applications include the plastics and rubber industry where they are used in extrusion and moulding machinery\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e170mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32162801811490,"sku":"259328","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F0259328-01_6eded89d-9069-40f9-9890-84c6af68d31e.webp?v=1792100475"},{"product_id":"rs-pro-2194725","title":"RS PRO Type J Thermocouple 150mm Length, 4.5mm Diameter, -60°C → 350°C; 219-4725","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type K \u0026amp; Type J IEC Heavy Duty Glassfibre Insulated Thermocouple Probes\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K and Type J thermocouple probes with a rugged construction that conform to IEC 584 standards. These thermocouple temperature probes have a 150 mm long, 4.5 mm diameter stainless steel probe sheath for protection against corrosion. The cable has a durable design with glassfibre insulation surrounded by a stainless steel overbraid. These thermocouples have a grounded hot junction which enables them to have a fast response time\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes. A thermocouple consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Grounded Junction?\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged stainless steel probe sheath for protection against corrosion\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eWelded, grounded junction for fast response times\u003c\/li\u003e\n\u003cli\u003eRugged glassfibre insulated cable with stainless steel overbraid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003cp\u003eType J Thermocouples (Iron-Constantan) have a smaller temperature range and a shorter lifespan at higher temperatures than the Type K but has the same reliability. Type J thermocouples are ideal for monitoring the temperatures of inert materials and in vacuum applications. Applications include heat processes such as the manufacturing of plastic and resin and in electrical furnaces\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e4.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163057565730,"sku":"2194725","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F2194725-01_ab8a0ca1-736a-4230-9f3a-ff9c04a25bb3.webp?v=1792100666"},{"product_id":"rs-pro-3342622","title":"RS PRO Type K Thermocouple 20mm Length, 5mm Diameter, -40°C → 750°C; 334-2622","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Type J \u0026amp; Type K Grounded Junction Braided Thermocouple\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro Type J and Type K thermocouple temperature sensors conforming to to IEC 584 standards with a Class 1 tolerance for optimum performance. These thermocouple temperature probes have a rugged design with a 5 mm diameter, 2.5 m twin conductor cable insulated by glass silk and steel braid. The probe is enclosed in a stainless steel sheath for protection against corrosion. These thermocouples feature a grounded hot junction for a fast response time.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Grounded Junction?\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eGrounded hot junction for a fast response time\u003c\/li\u003e\n\u003cli\u003eClass 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eRugged design with steel braided cable\u003c\/li\u003e\n\u003cli\u003eStainless steel sheath for corrosion resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003cp\u003eType J Thermocouples (Iron-Constantan) have a smaller temperature range and a shorter lifespan at higher temperatures than the Type K but has the same reliability. Type J thermocouples are ideal for monitoring the temperatures of inert materials and in vacuum applications. Applications include heat processes such as the manufacturing of plastic and resin and in electrical furnaces\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+750°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e316L Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163073556514,"sku":"3342622","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3342622-01_a550a113-c9fd-4d92-896d-aac594bab4f9.webp?v=1792100670"},{"product_id":"rs-pro-151271","title":"RS PRO Type T Thermocouple 100mm Length, 1.6mm Diameter, -75°C → +250°C; 151-271","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eType T Thermocouple, Stainless Steel 100mm Hypodermic Probe\u003c\/h3\u003e\n\u003cp\u003eCan be steam sterilised\u003c\/p\u003e\n\u003cp\u003e1.5m of PTFE cable\u003c\/p\u003e\n\u003cp\u003eTemperature range -75 → +250 °C\u003c\/p\u003e\n\u003cp\u003eOld Colour Code, BS1843\u003c\/p\u003e\n\u003cp\u003eThermocouples, bayonet adaptors, compensating and extension cables and connectors.,These BS1843 products are being phased out, having been replaced with a new colour code standard BS4937 Part 30 1993 (IEC 584-3 1989 modified for international use). System Calibration is available on selected probes and includes the full charge of the instrument and probe.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1.6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eConstantan, Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eBS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163236806690,"sku":"151271","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F0151271-01_ff93082c-4c1a-46f2-ac5d-86675c4d8a05.webp?v=1792100675"},{"product_id":"rs-pro-6212388","title":"RS PRO Type J Thermocouple 200mm Length, 6mm Diameter, 0°C → +700°C; 621-2388","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eType J and K Probes and KNE Terminal Head Assembly\u003c\/h3\u003e\n\u003cp\u003e200400 and 600mm versions\u003c\/p\u003e\n\u003cp\u003eStainless steel sheath\u003c\/p\u003e\n\u003cp\u003eInsulated tip junction\u003c\/p\u003e\n\u003cp\u003eAluminium IP67 terminal head\u003c\/p\u003e\n\u003cp\u003ePush-in process connection\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eAll have a temperature range of -100 to 1100°C\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e316L Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+700°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eConnection Head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163297493026,"sku":"6212388","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212388-01_4eadd14f-76d6-46c0-99bc-c927520c26a6.webp?v=1792100670"},{"product_id":"rs-pro-8140153","title":"RS PRO Type T Thermocouple 2m Length, 0.2 mm, 0.3 mm Diameter, -75°C → +250°C; 814-0153","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro PFA Type K and T Exposed Welded Tip Thermocouples\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type T and K bare wire thermocouple temperature sensors with a tolerance to ANSI MC96.1 class 1 for optimum accuracy. These thermocouple temperature sensors have a durable construction a welded exposed junction for a fast response time. One end of the thermocouple is terminated with a miniature plug for a quick and easy connection. The twin twisted leads of these thermocouple sensors are insulated with durable Teflon PFA.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eA welded exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelded, exposed junction for fast response times\u003c\/li\u003e\n\u003cli\u003eDurable construction with PFA insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003cli\u003eTolerance to ANSI MC96.1 Class 1 for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eMiniature plug termination for quick and easy connection\u003c\/li\u003e\n\u003cli\u003eTemperature range of -75 to +250°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese grounded junction Type K and T bare wire thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eClass 1 cable specification in accordance with BS EN 60584-3:2008\u003c\/p\u003e\n\u003cp\u003eANSI MC96.1 class 1\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003cp\u003eSmall Pack Size:814-0153\u003c\/p\u003e\n\u003cp\u003eLarge Pack Size:262-3219\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eColour\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eTranslucent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eLength\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e600mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThickness\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eWidth\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e600mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eDensity\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1.2g\/cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Operating Temperature\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+230°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMinimum Operating Temperature\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e-60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eElongation\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163444064290,"sku":"8140153","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F8140153-01_be8ec784-4c8c-440c-9a7e-eb1855c58986.webp?v=1792100679"},{"product_id":"rs-pro-6212287","title":"RS PRO Type K Thermocouple Copper probe 6.35mm Diameter, 0°C → +200°C; 621-2287","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Type J and Type K Thermocouple with Self Adhesive Copper Patch\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro IEC 584 standard Type J and Type K thermocouple temperature sensors designed for taking surface temperature measurements. The thermocouple lead has a durable Teflon PFA insulation and an ungrounded welded hot junction for a reduction in electrical interference. The end of the thermocouple lead is terminated with a 6.35 mm diameter self adhesive copper pad for attaching to a surface.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Surface Thermocouple?\u003c\/h3\u003e\n\u003cp\u003eThis thermocouple is designed for measuring the temperature on a surface. Most thermocouples have a sensing tip where there ends of the thermocouple wires are encased in sheaths or protection tubes which do not allow for measuring the temperature of a surface area. Surface temperature sensing thermocouples overcome this problem by having the sensing tip housed in a magnet or adhesive patch. The patch or magnet is then securely attached to the surface to be measured to provide a true surface contact. This affixing method allows these thermocouples to be used on many types of surfaces including uneven and circular surfaces. They are also simple to use and easy to replace and position.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConforms to IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eUngrounded hot junction for reduction in electrical intereference\u003c\/li\u003e\n\u003cli\u003eSelf adhesive copper patch for accurate surface sensing\u003c\/li\u003e\n\u003cli\u003eDurable Teflon PFA insulated leads for resistance to oils, acid, fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eBoth these surface mount thermocouple are ideal for use for permanent or temporary measurement in a range of applications including HVAC, air conditioning, plumbing and temperature mapping\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e6.35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163710402594,"sku":"6212287","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212287-01_57c75ae7-c8cc-4cd5-9fa7-7e8837d89fc9.webp?v=1792100879"},{"product_id":"rs-pro-2194387","title":"RS PRO Type K Thermocouple 500mm Length, 3mm Diameter, 0°C → 1100°C; 219-4387","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Mineral Insulated Type K Thermocouple with Threaded Pot and Tails\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of type K thermocouple temperature sensors or probes that conform to IEC 584 specifications. These thermocouple temperature probes have durable construction with a 310 stainless steel mineral insulated flexible probe sheath that can be bent and formed to suit a wide range of applications. The thermocouple has a single element insulated hot junction for a reduction in electrical interference and a M8 x 1.00 mm fine pitch threaded pot seal with a temperature rating of 200°C.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is an Insulated Junction?\u003c\/h3\u003e\n\u003cp\u003eAn insulated or ungrounded junction is where the thermocouple wires are welded together and fully covered by but insulated from the outer protective sheath, often by the use of mineral insulation. The advantage of this is that there is a reduction in electrical interference and a stable reading\u003c\/p\u003e\n\u003ch3\u003eWhat is Mineral Insulation?\u003c\/h3\u003e\n\u003cp\u003eMineral insulation is used to insulate the thermocouple wires from one another and from the metal probe sheath that surrounds them. The sheath is filled with a highly compacted magnesium oxide powder that prevents the conductors from making contact with one another other than at the fixed junction. The high density of the mineral powder enables the thermocouple to have a rapid response as it promotes a fast heat transfer between the conductor and the sheath. Mineral insulation also helps to protect the thermocouple wire from environmental damage including corrosion, prevents electrical interference and allows the cable to be flexible whilst maintaining its mechanical strength\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsulated hot junction for reduced electrical interference\u003c\/li\u003e\n\u003cli\u003eMineral insulation for flexibility, durability and high performance\u003c\/li\u003e\n\u003cli\u003eConforms to IEC 584 standards\u003c\/li\u003e\n\u003cli\u003eFlexible, can be bent into shape for easy installation\u003c\/li\u003e\n\u003cli\u003e310 stainless steel sheath for resistance to corrosion and oxidation\u003c\/li\u003e\n\u003cli\u003eM8 x 1.0 mm fine pitch threaded pot seal\u003c\/li\u003e\n\u003cli\u003eWide temperature range of -100 to +1100°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eType K Thermocouples (Nickel-Chromium \/ Nickel-Aluminium) are the most common type of thermocouple and are both accurate and flexible with a wide temperature range. Typical applications for these mineral insulated Type-K thermocouple probes include heat exchangers, power stations, brick and cement kilns, heat treatment and annealing furnaces, thermostats, food thermometers, vehicle diagnostics and in laboratories\u003c\/p\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003eM8 lock nuts are available, please see stock numbers 762-1162 and 762-1187\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163722854434,"sku":"2194387","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F2194387-01_d7c47e15-f839-418e-aef5-dc8b28c5f301.webp?v=1792100896"},{"product_id":"rs-pro-6212221","title":"RS PRO Type K Thermocouple 175mm Length, 6mm Diameter, -50°C → 1100°C; 621-2221","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro Type J and K IEC Thermocouples with Adjustable Bayonet Probe\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J and Type K thermocouple temperature sensors that conform to IEC 60584 standards with a grounded hot junction for a fast resposne time. These durable type J and Type K thermocouples have a 2 m long wire with glass fibre insulation and a stainless steel braid. The probe is fitted with an adjustable spring loaded bayonet probe to enable it to be fitted securely.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Grounded Junction?\u003c\/h3\u003e\n\u003cp\u003eIn a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.\u003c\/p\u003e\n\u003ch3\u003eWhat is an Adjustable Bayonet Probe\u003c\/h3\u003e\n\u003cp\u003eThe probes of these thermocouple sensors have an adjustable screw threaded spring 175 mm long with a slotted bayonet fixing cap. The bayonet cap screws along this spring and allows the immersion length of the thermocouple probe to be adjusted. Once in place the bayonet cap is secured to a bayonet adapter (which must be purchased separately - see stock number 621-2243) allowing the thermocouple to be firmly held in place within the recess. The advantages of this method of fixing are;\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImmersion depth can be adjusted easily\u003c\/li\u003e\n\u003cli\u003eSecure connection within machine recess\u003c\/li\u003e\n\u003cli\u003ePositive pressure at the thermocouple tip and full immersion in process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable bayonet probe\u003c\/li\u003e\n\u003cli\u003eGrounded hot junction\u003c\/li\u003e\n\u003cli\u003eFast response time\u003c\/li\u003e\n\u003cli\u003eRugged glass fibre insulated wire with stainless steel overbraid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese Type J and Type K adjustable bayonet probe thermocouples are designed for direct installation into the process. The bayonet fitting makes them suited for applications where the thermocouple sensor tip is fitted directly into a drilled hole or recess in machinery. Typical applications include the plastics and rubber industry where they are used in extrusion and moulding machinery\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003eIEC-BS 4937 60584-2 \u0026amp; IEC-BS 4937 60584-3\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e175mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+1100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eRoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eResponse Time\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e0.7 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163770794018,"sku":"6212221","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F6212221-01_1cc0a0ac-f1a8-4d82-bbe9-899b96c3e737.webp?v=1792100885"},{"product_id":"rs-pro-8919126","title":"RS PRO Type T Thermocouple 150mm Length, 3mm Diameter, -100°C → 400°C; 891-9126","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS PRO Type T Thermocouple 150 mm Length, 3 mm Diameter, +400°C\u003c\/h3\u003e\n\u003cp\u003eUse this Type T thermocouple from the RS PRO range to measure temperatures of up to +400ºC. Thanks to the insulated single-element hot junction, the thermocouple can measure corrosive substances. This feature also ensures accurate readings as it reduces the electrical interference in the measuring circuit.\u003c\/p\u003e\n\u003cp\u003eThe thermocouple's sheath is flexible, allowing you to bend it with ease to suit your needs. This sheath is also made from a robust 316-grade stainless steel material that's resistant to corrosion, meaning it's long-lasting and suitable for use in harsh environments. The component has a threaded pot and tails that provide additional flexibility when setting it up.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable length of 100 mm\u003c\/li\u003e\n\u003cli\u003eMaximum temperature sensed of +400ºC\u003c\/li\u003e\n\u003cli\u003eProbe diameter of 3 mm\u003c\/li\u003e\n\u003cli\u003eProbe length of 150 mm\u003c\/li\u003e\n\u003cli\u003eProbe material of 316-grade stainless steel\u003c\/li\u003e\n\u003cli\u003eIEC (International Electrotechnical Commission) standards met\u003c\/li\u003e\n\u003cli\u003eCable termination type\u003c\/li\u003e\n\u003cli\u003eType T thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Material\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163772661794,"sku":"8919126","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F8919126-01_2ae5d406-4b3b-4e77-a772-3774dc34d197.webp?v=1792100887"},{"product_id":"rs-pro-3630266","title":"RS PRO Type T Thermocouple 1m Length, 1\/0.2mm Diameter, -75°C → +250°C; 363-0266","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS Pro IEC Type J, K \u0026amp; Type T Fine Wire Exposed Junction Thermocouple and Miniature Plug\u003c\/h3\u003e\n\u003cp\u003eFrom RS Pro a range of Type J, K and Type T fine wire temperature sensing thermocouples that conform to IEC-584-3 standards with a Class 1 tolerance for optimum performance. These Type K and Type T fine wire temperature sensors have a durable Teflon PTFE insulated class 1 twin-twisted 1\/0.2 mm lead. The lead is terminated with a rewireable miniature flat pin plug for a quick and easy connection. These thermocouples have an exposed welded junction which enables them to operate with a fast response time.\u003c\/p\u003e\n\u003ch3\u003eHow does a Thermocouple Work?\u003c\/h3\u003e\n\u003cp\u003eA thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect\u003c\/p\u003e\n\u003ch3\u003eWhat is a Welded Exposed Junction?\u003c\/h3\u003e\n\u003cp\u003eAn exposed junction is where the thermocouple wires are welded together but not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC-584-3 class 1 tolerance for optimum accuracy\u003c\/li\u003e\n\u003cli\u003eMiniature plug for quick and easy connection\u003c\/li\u003e\n\u003cli\u003eExposed welded junction for fast response\u003c\/li\u003e\n\u003cli\u003eDurable Teflon PTFE insulation for resistance to oils, acids and fluids and good mechanical strength and flexibility\u003c\/li\u003e\n\u003cli\u003eTemperature range from -75 to +250°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThese Type J, K and Type T fine wire thermocouple temperature sensors are ideal for test and development applications including test and measurement, temperature mapping and OEM applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1\/0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163774300194,"sku":"3630266","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F3630266-01_05e7ad3f-d4af-4723-b267-42034e098668.webp?v=1792100888"},{"product_id":"rs-pro-1236330","title":"RS PRO Type T Thermocouple 7\/0.2mm Diameter, -75°C → +250°C; 123-6330","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eDurable Type K, J \u0026amp; T Exposed Welded Tip Thermocouples\u003c\/h3\u003e\n\u003cp\u003eVarious types of exposed junction thermocouples with fitted miniature plug and insulated leads, ideal for test and develoment applications.\u003c\/p\u003e\n\u003cp\u003eThermocouple types K, J \u0026amp; T to IEC 584\u003c\/p\u003e\n\u003cp\u003eFast response, welded exposed junction\u003c\/p\u003e\n\u003cp\u003eDurable Teflon construction with choice of conductor size, 1\/0.315mm solid or 7\/0.2mm stranded\u003c\/p\u003e\n\u003cp\u003eMiniature plug termination\u003c\/p\u003e\n\u003cp\u003eTemperature range -75 → +250 °C\u003c\/p\u003e\n\u003cp\u003eIdeal for test \u0026amp; development applications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e7\/0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163819651106,"sku":"1236330","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F1236330-01_1bf41aeb-759f-45eb-ae5c-45d806cb2ff6.webp?v=1792101097"},{"product_id":"rs-pro-7621124","title":"RS PRO Type T Thermocouple 7\/0.2mm Diameter, -75°C → +250°C; 762-1124","description":"\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#ccc;border-spacing:0;}\n.tg td{background-color:#fff;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#f0f0f0;border-color:#ccc;border-style:solid;border-width:1px;color:#333;\nfont-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-tq73{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-93u6{font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;vertical-align:top}\n.tg .tg-cah6{font-family:Arial, Helvetica, sans-serif !important;;font-size:20px;font-weight:bold;text-align:left;vertical-align:top\n}\n.tg .tg-88o2{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;font-weight:bold;\ntext-align:left;vertical-align:top}\n.tg .tg-cv01{background-color:#f9f9f9;font-family:Arial, Helvetica, sans-serif !important;;font-size:18px;text-align:left;\nvertical-align:top}\n@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eRS PRO Type T Thermocouple 5 m Length, 7\/0.2 mm Diameter, +250°C\u003c\/h3\u003e\n\u003cp\u003eThis RS PRO Type T thermocouple lets you measure temperatures quickly and accurately. It's suitable for sensing temperatures of up to +250°C.\u003c\/p\u003e\n\u003cp\u003eThis thermocouple includes a welded exposed junction to guarantee a rapid response time. The exposed junction, also known as a measuring junction, is extremely sensitive, allowing you to get more precise temperature measurements. For flexibility and chemical resistance, the leads are insulated with a PFA (perfluoroalkoxy) Teflon material, making it a durable choice for use in demanding industrial settings.\u003c\/p\u003e\n\u003cp\u003eThe unit has a miniature flat pin plug on one end, making it simple to attach and detach. It's frequently used in testing and development applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable length of 5 m\u003c\/li\u003e\n\u003cli\u003eMaximum temperature sensed of +250°C\u003c\/li\u003e\n\u003cli\u003eProbe diameter of 7\/0.2 mm\u003c\/li\u003e\n\u003cli\u003eProbe length of 5 m\u003c\/li\u003e\n\u003cli\u003eIEC (International Electrotechnical Commission) standards met\u003c\/li\u003e\n\u003cli\u003eMiniature plug termination type\u003c\/li\u003e\n\u003cli\u003eType T thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-cah6\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eThermocouple Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eProbe Diameter\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e7\/0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eProbe Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eMaximum Temperature Sensed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e+250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eTermination Type\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eMiniature Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2evf\"\u003e\u003cstrong\u003eCable Length\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-2evf\"\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-z2iy\"\u003e\u003cstrong\u003eStandards Met\u003cstrong\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-z2iy\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"RS PRO","offers":[{"title":"Default Title","offer_id":32163847569442,"sku":"7621124","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/files\/F7621124-01_a8b6168a-c8dc-4234-833d-7e17e7b8f9bb.webp?v=1792101079"}],"url":"https:\/\/chanhvinh.com\/collections\/thermocouples.oembed?page=133","provider":"CÔNG TY CHÁNH VINH (Vật tư công nghiệp)","version":"1.0","type":"link"}