{"product_id":"sick-fla-diag00001","title":"Flexi Loop FLEXIL Flexi Loop \/ Module For Field Diagnostics, 16.8 → 30 V dc [FLA-DIAG00001]; 213-3766","description":"\u003cstyle type=\"text\/css\"\u003e@media screen and (max-width: 767px) {.tg {width: auto !important;}.tg col {width: auto !important;}.tg-wrap {overflow-x: auto;-webkit-overflow-scrolling: touch;}}\u003c\/style\u003e\n\u003cdiv class=\"cv-desc\"\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003ch3\u003eAt a glance\u003c\/h3\u003e\n\u003ch3\u003eYour Benefit\u003c\/h3\u003e\n\u003cp\u003eFlexi Loop can connect up to 32 safety sensors in series in compliance with the highest performance level PL e. Safety switches and safety sensors with OSSD outputs can be used together, regardless of manufacturer. Detailed diagnostic information is also available for each sensor or switch. Integrated switching signals allow for the use of interlocks, switches, and lamps. All sensors are supplied with voltage directly from the Flexi Loop. Unshielded standard cables are used with M12 male connectors. Ultimately, Flexi Loop can be relied upon for maximum safety. Connecting sensors in series reduces the amount of wiring and the number of safety inputs in the control cabinet. It also provides a comprehensive diagnostic check of all doors, emergency stop pushbuttons, and sensors. In conjunction with Flexi Soft and Flexi Classic, the entire safety application is able to cost-effectively meet customer needs.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eConnecting both safety switches and safety sensors with OSSD outputs in series minimizes the amount of wiring and the number of inputs at the safety controller, thus reducing costs.\u003c\/p\u003e\n\u003cp\u003eSimple calculation of the performance level saves time since the Flexi Loop node monitors each sensor individually\u003c\/p\u003e\n\u003cp\u003eQuick and easy configuration saves time\u003c\/p\u003e\n\u003cp\u003eAbility to be used over long distances increases application flexibility\u003c\/p\u003e\n\u003cp\u003eDetailed diagnostic information – who switched and why? minimizes system downtime\u003c\/p\u003e\n\u003cp\u003eSeamless system integration and communication with other SICK safety controllers\u003c\/p\u003e\n\u003cp\u003eDetailed status information on Flexi Loop components, diagnostic accessories, and safety controller enable quick and easy field diagnosticsSeries connection of 32 sensors with up to 100 m per segment in compliance with performance level PL e\u003c\/p\u003e\n\u003cp\u003eCompatible with sensors from all manufacturers\u003c\/p\u003e\n\u003cp\u003eDetailed diagnostic information\u003c\/p\u003e\n\u003cp\u003eIntegrated standard inputs and outputs\u003c\/p\u003e\n\u003cp\u003eVoltage supply for sensors is included\u003c\/p\u003e\n\u003ch3\u003eNote\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tg-wrap\"\u003e\u003ctable style=\"border-collapse:collapse;border-color:#ccc;border-spacing:0\" class=\"tg\"\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth style=\"background-color:#f0f0f0;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:18px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:bottom;word-break:normal\" colspan=\"2\"\u003eTHÔNG SỐ KỸ THUẬT\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eSICK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eFLA-DIAG00001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eFlexi Loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eFLEXIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eFlexi Loop \/ Module For Field Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eFor Use With\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eFlexi Soft System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"background-color:#f9f9f9;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e16.8 → 30 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;font-weight:bold;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"background-color:#fff;border-color:inherit;border-style:solid;border-width:1px;color:#333;font-family:Arial, Helvetica, sans-serif !important;font-size:16px;overflow:hidden;padding:10px 5px;text-align:left;vertical-align:middle;word-break:normal\"\u003e68.15 x 48 x 18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eGiá: \u003cstrong\u003eLiên hệ\u003c\/strong\u003e – gửi mã và số lượng về CV@chanhvinh.com để nhận báo giá nhanh.\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":39415154966562,"sku":"2133766","price":0.0,"currency_code":"VND","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0289\/0180\/2018\/products\/Y2133766-01.jpg?v=1630285163","url":"https:\/\/chanhvinh.com\/products\/sick-fla-diag00001","provider":"CÔNG TY CHÁNH VINH (Vật tư công nghiệp)","version":"1.0","type":"link"}