| Manufacturer |
FLUKE |
| Manufacturer Part No. |
FLUKE-789/E |
| Type of meter |
multimeter calibrator |
| Diode test |
0.3mA @600mV |
| Kind of display used |
LCD |
| DC voltage measuring range |
1...400mV/4V/40V/400V/1kV |
| DC voltage measuring accuracy |
±(0.1% + 1 digit) |
| AC voltage measuring range |
0.1...400mV/4V/40V/400V/1kV |
| AC voltage measuring accuracy |
±(1.2% + 4 digit) |
| DC current measuring range |
1µA...30mA/1A |
| DC current measuring accuracy |
±(0.2% + 2 digit) |
| AC current measuring range |
0.001mA...1A |
| AC current measuring accuracy |
±(1% + 2 digit) |
| Resistance measuring range |
100mΩ...400Ω/4kΩ/400kΩ/4MΩ/40MΩ |
| Resistance measuring accuracy |
±(0.2%+1 digit) |
| Frequency measuring range |
10mHz...199.99Hz/1999.9Hz/19.99kHz |
| Frequency measuring accuracy |
±(0.005%+1 digit) |
| Continuity test |
acoustic indication, <100Ω |
| Dimensions |
203x100x50mm |
| Measurement |
AC current, AC voltage, DC current, DC voltage, frequency, resistance |
| Conform to the norm |
CAT III 1000V CAT IV 600V EN 61010 EN 61243-3:2010 |
| Interface |
IrDA |
| Software |
Fluke Connect (FLK-IR3000FC) |
| Power supply |
battery LR6 AA 1,5V x4 |
| Measuring instrument features |
0% or 100% of signal value (4mA, 20mA) source function, 24V loop supply voltage, automatic and manual setting of step function, HART range with loop and built-in 250Ω resistor, HOLD function, impact resistant holster, MIN/MAX/MEAN/REL function, simultaneous readout in mA and % of range, source DC current / calibrate loop current, source/simulate |
| Standard equipment |
crocodile clips FLK-AC72, FLK-TL75 test leads |
| Optional equipment |
240A AC/DC FLK-I200S current clamp probe, 400A AC/DC FLK-I410 current clamp probe, crocodile clip FLK-AC89, crocodile clip FLK-AC220, crocodile clip FLK-AC283, crocodile clip FLK-AC285, FLK-C510 - soft cover, FLK-FVF-SC2 software, FLK-TL225 set |
| Battery/ rechargeable battery |
battery LR6 AA 1,5V x4 |
| Gross weight |
970.9 g |
| EAN code |
95969590396 |